-- Machine generated MIB file, do not edit! -- -- MIB file for DVD5480-H, type code 08.E2, software label 1110 -- Generated on Monday, 19-Sep-22 15:09:57 CEST -- CVS $Id: DVD5480-H_08e2_sw1110.mib,v 1.2 2022/09/19 13:09:57 til Exp $ -- -- Copyright 2003-2022 by LYNX Technik AG -- -- These coded instructions, statements, and computer programs contain -- unpublished proprietary information written by LYNX Technik AG and -- are protected by Federal copyright law. They may not be disclosed -- to third parties or copied or duplicated in any form, in whole or -- in part, without the prior written consent of LYNX Technik AG. -- DVD5480-H-08e2-sw1110-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, TimeTicks FROM SNMPv2-SMI -- RFC2578 TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC -- RFC2579 MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF -- RFC2580 mib-modules, products, FixedPointValue1, FixedPointValue2, FixedPointValue3, OnOffValue FROM LYNX-SMI; dvd5480-h-08e2-sw1110 MODULE-IDENTITY LAST-UPDATED "202209191309Z" ORGANIZATION "LYNX Technik AG" CONTACT-INFO "LYNX Technik AG Brunnenweg 3 64331 Weiterstadt http://www.lynx-technik.com mailto:support@lynx-technik.com" DESCRIPTION "MIB module definition for DVD5480-H, type code 08.E2, software label 1110" REVISION "202209191309Z" DESCRIPTION "Generated by LYNX Asset Database" ::= { mib-modules 2275110 } dvd5480-h-08e2 OBJECT-IDENTITY STATUS current DESCRIPTION "LYNX device type DVD5480-H" ::= { products 2274 } sw1110 OBJECT-IDENTITY STATUS current DESCRIPTION "Software label 1110" ::= { dvd5480-h-08e2 1110 } -- Type definitions TypeFactoryReset ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { press(0) } TypeStatusColor ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { unknown(0), black(1), green(2), yellow(3), red(4) } TypeEventPrimaryPowermissingSNMP ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { none(0), onOnly(1), offOnly(2), onOff(3) } TypeInputStatus1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { unknown(0), missing(1), present(2), n270Mbps(3), n740Mbps(4), n15Gbps(5), n30Gbps(6), n6Gbps(7), n12Gbps(8) } TypeTranscoderMode1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { demux(0), mux(1), bypass(2) } TypeBypassSource11 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { r1(0), r2(1), r3(2), r4(3), r5(4), r6(5), r7(6), r8(7), muxLoopback(8) } TypeMuxSource11 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { r1(0), r2(1), r3(2), r4(3), r5(4), r6(5), r7(6), r8(7) } TypeBNCPortDirection2 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { input(0), output(1) } TypeTranscoderRate1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { n12G4X3G(0), n6G4X15G(1) } TypeTranscoder6GQuadLinkVPIDCoding1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { iTURBT1120(0), iTURBT2077(1) } -- Parameter definitions typeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LYNX product type name" ::= { paramEntry 1 } displayName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name of device (potentially user-defined), as stored in device-controller" ::= { paramEntry 2 } position OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Full-qualified position information (e.g. as used in address-field of remoteIF protocol)" ::= { paramEntry 3 } uptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Connection time of the device to this UI (in seconds)" ::= { paramEntry 4 } type OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device type code" ::= { paramEntry 5 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device version information" ::= { paramEntry 6 } factoryReset OBJECT-TYPE SYNTAX TypeFactoryReset MAX-ACCESS read-write STATUS current DESCRIPTION "Reset device to factory default values (set value to PRESS for execution)" ::= { paramEntry 7 } lock OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "Lock Device" ::= { paramEntry 8 } locate OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "toggle the locating function (yellow flashing master LED) ON/OFF" ::= { paramEntry 9 } statusColor OBJECT-TYPE SYNTAX TypeStatusColor MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED (red/green/yellow)" ::= { paramEntry 10 } statusColorRGB OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED as #RRGGBB" ::= { paramEntry 11 } statusText OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current status text (OK or error-details)" ::= { paramEntry 12 } boardID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "BoardID" ::= { paramEntry 13 } eventPrimaryPowermissing OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Info Event: Primary Power missing" ::= { paramEntry 15 } eventRedundantPowermissing OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Info Event: Redundant Power missing" ::= { paramEntry 16 } eventSDIInput1NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Warning Event: SDI Input 1 No Input" ::= { paramEntry 17 } eventSDIInput2NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Warning Event: SDI Input 2 No Input" ::= { paramEntry 18 } eventSDIInput3NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Warning Event: SDI Input 3 No Input" ::= { paramEntry 19 } eventSDIInput4NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Warning Event: SDI Input 4 No Input" ::= { paramEntry 20 } eventSDIInput5NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Warning Event: SDI Input 5 No Input" ::= { paramEntry 21 } eventSDIInput6NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Warning Event: SDI Input 6 No Input" ::= { paramEntry 22 } eventSDIInput7NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Warning Event: SDI Input 7 No Input" ::= { paramEntry 23 } eventSDIInput8NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Warning Event: SDI Input 8 No Input" ::= { paramEntry 24 } eventPrimaryPowermissingSNMP OBJECT-TYPE SYNTAX TypeEventPrimaryPowermissingSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: Primary Power missing" ::= { paramEntry 25 } eventRedundantPowermissingSNMP OBJECT-TYPE SYNTAX TypeEventPrimaryPowermissingSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: Redundant Power missing" ::= { paramEntry 26 } eventSDIInput1NoInputSNMP OBJECT-TYPE SYNTAX TypeEventPrimaryPowermissingSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 1 No Input" ::= { paramEntry 27 } eventSDIInput2NoInputSNMP OBJECT-TYPE SYNTAX TypeEventPrimaryPowermissingSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 2 No Input" ::= { paramEntry 28 } eventSDIInput3NoInputSNMP OBJECT-TYPE SYNTAX TypeEventPrimaryPowermissingSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 3 No Input" ::= { paramEntry 29 } eventSDIInput4NoInputSNMP OBJECT-TYPE SYNTAX TypeEventPrimaryPowermissingSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 4 No Input" ::= { paramEntry 30 } eventSDIInput5NoInputSNMP OBJECT-TYPE SYNTAX TypeEventPrimaryPowermissingSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 5 No Input" ::= { paramEntry 31 } eventSDIInput6NoInputSNMP OBJECT-TYPE SYNTAX TypeEventPrimaryPowermissingSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 6 No Input" ::= { paramEntry 32 } eventSDIInput7NoInputSNMP OBJECT-TYPE SYNTAX TypeEventPrimaryPowermissingSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 7 No Input" ::= { paramEntry 33 } eventSDIInput8NoInputSNMP OBJECT-TYPE SYNTAX TypeEventPrimaryPowermissingSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 8 No Input" ::= { paramEntry 34 } inputStatus1 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status R1 In" ::= { paramEntry 35 } inputStatus2 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status R2/T1 In" ::= { paramEntry 36 } inputStatus3 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status R3/T2 In" ::= { paramEntry 37 } inputStatus4 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status R4/T4 In" ::= { paramEntry 38 } inputStatus5 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status R5 In" ::= { paramEntry 39 } inputStatus6 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status R6/T5 In" ::= { paramEntry 40 } inputStatus7 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status R7/T6 In" ::= { paramEntry 41 } inputStatus8 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status R8/T8 In" ::= { paramEntry 42 } outputStatus1 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status R2/T1 Out" ::= { paramEntry 43 } outputStatus11 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status T1 Out" ::= { paramEntry 44 } outputStatus2 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status R3/T2 Out" ::= { paramEntry 45 } outputStatus3 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status T3 Out" ::= { paramEntry 46 } outputStatus4 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status R4/T4 Out" ::= { paramEntry 47 } outputStatus5 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status R6/T5 Out" ::= { paramEntry 48 } outputStatus51 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status T5 Out" ::= { paramEntry 49 } outputStatus6 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status R7/T6 Out" ::= { paramEntry 50 } outputStatus7 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status T7 Out" ::= { paramEntry 51 } outputStatus8 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status R8/T8 In" ::= { paramEntry 52 } transcoderMode1 OBJECT-TYPE SYNTAX TypeTranscoderMode1 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Mode for Transcoder 1" ::= { paramEntry 53 } transcoderMode2 OBJECT-TYPE SYNTAX TypeTranscoderMode1 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Mode for Transcoder 2" ::= { paramEntry 54 } bypassSource11 OBJECT-TYPE SYNTAX TypeBypassSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 1.1 Bypass Mode" ::= { paramEntry 55 } bypassSource21 OBJECT-TYPE SYNTAX TypeBypassSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 2.1 Bypass Mode" ::= { paramEntry 56 } muxSource11 OBJECT-TYPE SYNTAX TypeMuxSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 1.1 Mux Mode" ::= { paramEntry 57 } muxSource21 OBJECT-TYPE SYNTAX TypeMuxSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 2.1 Mux Mode" ::= { paramEntry 58 } transcoderStatus11 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Status of Transcoder 1.1" ::= { paramEntry 59 } transcoderStatus21 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Status of Transcoder 2.1" ::= { paramEntry 60 } bypassSource12 OBJECT-TYPE SYNTAX TypeBypassSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 1.2 Bypass Mode" ::= { paramEntry 61 } bypassSource22 OBJECT-TYPE SYNTAX TypeBypassSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 2.2 Bypass Mode" ::= { paramEntry 62 } muxSource12 OBJECT-TYPE SYNTAX TypeMuxSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 1.2 Mux Mode" ::= { paramEntry 63 } muxSource22 OBJECT-TYPE SYNTAX TypeMuxSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 2.2 Mux Mode" ::= { paramEntry 64 } transcoderStatus12 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Status of Transcoder 1.2" ::= { paramEntry 65 } transcoderStatus22 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Status of Transcoder 2.2" ::= { paramEntry 66 } bypassSource13 OBJECT-TYPE SYNTAX TypeBypassSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 1.3 Bypass Mode" ::= { paramEntry 67 } bypassSource23 OBJECT-TYPE SYNTAX TypeBypassSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 2.3 Bypass Mode" ::= { paramEntry 68 } muxSource13 OBJECT-TYPE SYNTAX TypeMuxSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 1.3 Mux Mode" ::= { paramEntry 69 } muxSource23 OBJECT-TYPE SYNTAX TypeMuxSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 2.3 Mux Mode" ::= { paramEntry 70 } transcoderStatus13 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Status of Transcoder 1.3" ::= { paramEntry 71 } transcoderStatus23 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Status of Transcoder 2.3" ::= { paramEntry 72 } bypassSource14 OBJECT-TYPE SYNTAX TypeBypassSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 1.4 Bypass Mode" ::= { paramEntry 73 } bypassSource24 OBJECT-TYPE SYNTAX TypeBypassSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 2.4 Bypass Mode" ::= { paramEntry 74 } muxSource14 OBJECT-TYPE SYNTAX TypeMuxSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 1.4 Mux Mode" ::= { paramEntry 75 } muxSource24 OBJECT-TYPE SYNTAX TypeMuxSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 2.4 Mux Mode" ::= { paramEntry 76 } transcoderStatus14 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Status of Transcoder 1.4" ::= { paramEntry 77 } transcoderStatus24 OBJECT-TYPE SYNTAX TypeInputStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Status of Transcoder 2.4" ::= { paramEntry 78 } demuxSource1 OBJECT-TYPE SYNTAX TypeBypassSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 1 Demux Mode" ::= { paramEntry 79 } demuxSource2 OBJECT-TYPE SYNTAX TypeBypassSource11 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Source for Transcoder 2 Demux Mode" ::= { paramEntry 80 } bNCPortDirection2 OBJECT-TYPE SYNTAX TypeBNCPortDirection2 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Port Direction of BNC Input 2" ::= { paramEntry 81 } bNCPortDirection3 OBJECT-TYPE SYNTAX TypeBNCPortDirection2 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Port Direction of BNC Input 3" ::= { paramEntry 82 } bNCPortDirection4 OBJECT-TYPE SYNTAX TypeBNCPortDirection2 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Port Direction of BNC Input 4" ::= { paramEntry 83 } bNCPortDirection6 OBJECT-TYPE SYNTAX TypeBNCPortDirection2 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Port Direction of BNC Input 6" ::= { paramEntry 84 } bNCPortDirection7 OBJECT-TYPE SYNTAX TypeBNCPortDirection2 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Port Direction of BNC Input 7" ::= { paramEntry 85 } bNCPortDirection8 OBJECT-TYPE SYNTAX TypeBNCPortDirection2 MAX-ACCESS read-write STATUS current DESCRIPTION "Set Port Direction of BNC Input 8" ::= { paramEntry 86 } hardwareMainVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Main Version" ::= { paramEntry 87 } hardwareMainBoard OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Main Board" ::= { paramEntry 88 } hardwareMainHWIndex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Main HW Index" ::= { paramEntry 89 } hardwareMainChangeIndex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Main Change Index" ::= { paramEntry 90 } hardwareMainSerial OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Main Serial" ::= { paramEntry 91 } hardwareMainDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Main Date" ::= { paramEntry 92 } hardwareBackVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Back Version" ::= { paramEntry 93 } hardwareBackBoard OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Back Board" ::= { paramEntry 94 } hardwareBackHWIndex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Back HW Index" ::= { paramEntry 95 } hardwareBackChangeIndex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Back Change Index" ::= { paramEntry 96 } hardwareBackSerial OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Back Serial" ::= { paramEntry 97 } hardwareBackDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Back Date" ::= { paramEntry 98 } transcoderRate1 OBJECT-TYPE SYNTAX TypeTranscoderRate1 MAX-ACCESS read-write STATUS current DESCRIPTION "Set the Data Rate for Mux/Demux Mode of Transcoder 1. Does not affect Bypass Mode." ::= { paramEntry 99 } transcoderRate2 OBJECT-TYPE SYNTAX TypeTranscoderRate1 MAX-ACCESS read-write STATUS current DESCRIPTION "Set the Data Rate for Mux/Demux Mode of Transcoder 2. Does not affect Bypass Mode." ::= { paramEntry 100 } transcoder6GQuadLinkVPIDCoding1 OBJECT-TYPE SYNTAX TypeTranscoder6GQuadLinkVPIDCoding1 MAX-ACCESS read-write STATUS current DESCRIPTION "Select which VPID Coding should be used for 6G Quad Links of Transcoder 1." ::= { paramEntry 101 } transcoder6GQuadLinkVPIDCoding2 OBJECT-TYPE SYNTAX TypeTranscoder6GQuadLinkVPIDCoding1 MAX-ACCESS read-write STATUS current DESCRIPTION "Select which VPID Coding should be used for 6G Quad Links of Transcoder 2." ::= { paramEntry 102 } -- Parameter table paramTable OBJECT-TYPE SYNTAX SEQUENCE OF ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of DVD5480-H parameters" ::= { sw1110 1 } paramEntry OBJECT-TYPE SYNTAX ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of DVD5480-H parameters" INDEX { IMPLIED position } ::= { paramTable 1 } ParamEntry ::= SEQUENCE { typeName DisplayString, displayName DisplayString, position OCTET STRING, uptime TimeTicks, type DisplayString, version DisplayString, factoryReset TypeFactoryReset, lock OnOffValue, locate OnOffValue, statusColor TypeStatusColor, statusColorRGB DisplayString, statusText DisplayString, boardID Integer32, eventPrimaryPowermissing OnOffValue, eventRedundantPowermissing OnOffValue, eventSDIInput1NoInput OnOffValue, eventSDIInput2NoInput OnOffValue, eventSDIInput3NoInput OnOffValue, eventSDIInput4NoInput OnOffValue, eventSDIInput5NoInput OnOffValue, eventSDIInput6NoInput OnOffValue, eventSDIInput7NoInput OnOffValue, eventSDIInput8NoInput OnOffValue, eventPrimaryPowermissingSNMP TypeEventPrimaryPowermissingSNMP, eventRedundantPowermissingSNMP TypeEventPrimaryPowermissingSNMP, eventSDIInput1NoInputSNMP TypeEventPrimaryPowermissingSNMP, eventSDIInput2NoInputSNMP TypeEventPrimaryPowermissingSNMP, eventSDIInput3NoInputSNMP TypeEventPrimaryPowermissingSNMP, eventSDIInput4NoInputSNMP TypeEventPrimaryPowermissingSNMP, eventSDIInput5NoInputSNMP TypeEventPrimaryPowermissingSNMP, eventSDIInput6NoInputSNMP TypeEventPrimaryPowermissingSNMP, eventSDIInput7NoInputSNMP TypeEventPrimaryPowermissingSNMP, eventSDIInput8NoInputSNMP TypeEventPrimaryPowermissingSNMP, inputStatus1 TypeInputStatus1, inputStatus2 TypeInputStatus1, inputStatus3 TypeInputStatus1, inputStatus4 TypeInputStatus1, inputStatus5 TypeInputStatus1, inputStatus6 TypeInputStatus1, inputStatus7 TypeInputStatus1, inputStatus8 TypeInputStatus1, outputStatus1 TypeInputStatus1, outputStatus11 TypeInputStatus1, outputStatus2 TypeInputStatus1, outputStatus3 TypeInputStatus1, outputStatus4 TypeInputStatus1, outputStatus5 TypeInputStatus1, outputStatus51 TypeInputStatus1, outputStatus6 TypeInputStatus1, outputStatus7 TypeInputStatus1, outputStatus8 TypeInputStatus1, transcoderMode1 TypeTranscoderMode1, transcoderMode2 TypeTranscoderMode1, bypassSource11 TypeBypassSource11, bypassSource21 TypeBypassSource11, muxSource11 TypeMuxSource11, muxSource21 TypeMuxSource11, transcoderStatus11 TypeInputStatus1, transcoderStatus21 TypeInputStatus1, bypassSource12 TypeBypassSource11, bypassSource22 TypeBypassSource11, muxSource12 TypeMuxSource11, muxSource22 TypeMuxSource11, transcoderStatus12 TypeInputStatus1, transcoderStatus22 TypeInputStatus1, bypassSource13 TypeBypassSource11, bypassSource23 TypeBypassSource11, muxSource13 TypeMuxSource11, muxSource23 TypeMuxSource11, transcoderStatus13 TypeInputStatus1, transcoderStatus23 TypeInputStatus1, bypassSource14 TypeBypassSource11, bypassSource24 TypeBypassSource11, muxSource14 TypeMuxSource11, muxSource24 TypeMuxSource11, transcoderStatus14 TypeInputStatus1, transcoderStatus24 TypeInputStatus1, demuxSource1 TypeBypassSource11, demuxSource2 TypeBypassSource11, bNCPortDirection2 TypeBNCPortDirection2, bNCPortDirection3 TypeBNCPortDirection2, bNCPortDirection4 TypeBNCPortDirection2, bNCPortDirection6 TypeBNCPortDirection2, bNCPortDirection7 TypeBNCPortDirection2, bNCPortDirection8 TypeBNCPortDirection2, hardwareMainVersion DisplayString, hardwareMainBoard DisplayString, hardwareMainHWIndex DisplayString, hardwareMainChangeIndex DisplayString, hardwareMainSerial DisplayString, hardwareMainDate DisplayString, hardwareBackVersion DisplayString, hardwareBackBoard DisplayString, hardwareBackHWIndex DisplayString, hardwareBackChangeIndex DisplayString, hardwareBackSerial DisplayString, hardwareBackDate DisplayString, transcoderRate1 TypeTranscoderRate1, transcoderRate2 TypeTranscoderRate1, transcoder6GQuadLinkVPIDCoding1 TypeTranscoder6GQuadLinkVPIDCoding1, transcoder6GQuadLinkVPIDCoding2 TypeTranscoder6GQuadLinkVPIDCoding1 } -- Conformance statements conformance OBJECT-IDENTITY STATUS current DESCRIPTION "Conformance declaration of DVD5480-H" ::= { sw1110 2 } paramGroup OBJECT-GROUP OBJECTS { typeName, displayName, position, uptime, type, version, factoryReset, lock, locate, statusColor, statusColorRGB, statusText, boardID, eventPrimaryPowermissing, eventRedundantPowermissing, eventSDIInput1NoInput, eventSDIInput2NoInput, eventSDIInput3NoInput, eventSDIInput4NoInput, eventSDIInput5NoInput, eventSDIInput6NoInput, eventSDIInput7NoInput, eventSDIInput8NoInput, eventPrimaryPowermissingSNMP, eventRedundantPowermissingSNMP, eventSDIInput1NoInputSNMP, eventSDIInput2NoInputSNMP, eventSDIInput3NoInputSNMP, eventSDIInput4NoInputSNMP, eventSDIInput5NoInputSNMP, eventSDIInput6NoInputSNMP, eventSDIInput7NoInputSNMP, eventSDIInput8NoInputSNMP, inputStatus1, inputStatus2, inputStatus3, inputStatus4, inputStatus5, inputStatus6, inputStatus7, inputStatus8, outputStatus1, outputStatus11, outputStatus2, outputStatus3, outputStatus4, outputStatus5, outputStatus51, outputStatus6, outputStatus7, outputStatus8, transcoderMode1, transcoderMode2, bypassSource11, bypassSource21, muxSource11, muxSource21, transcoderStatus11, transcoderStatus21, bypassSource12, bypassSource22, muxSource12, muxSource22, transcoderStatus12, transcoderStatus22, bypassSource13, bypassSource23, muxSource13, muxSource23, transcoderStatus13, transcoderStatus23, bypassSource14, bypassSource24, muxSource14, muxSource24, transcoderStatus14, transcoderStatus24, demuxSource1, demuxSource2, bNCPortDirection2, bNCPortDirection3, bNCPortDirection4, bNCPortDirection6, bNCPortDirection7, bNCPortDirection8, hardwareMainVersion, hardwareMainBoard, hardwareMainHWIndex, hardwareMainChangeIndex, hardwareMainSerial, hardwareMainDate, hardwareBackVersion, hardwareBackBoard, hardwareBackHWIndex, hardwareBackChangeIndex, hardwareBackSerial, hardwareBackDate, transcoderRate1, transcoderRate2, transcoder6GQuadLinkVPIDCoding1, transcoder6GQuadLinkVPIDCoding2 } STATUS current DESCRIPTION "Conformance group containing all device parameters" ::= { conformance 1 } paramCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance specification" MODULE -- This module MANDATORY-GROUPS { paramGroup } ::= { conformance 2 } END