-- Machine generated MIB file, do not edit! -- -- MIB file for DVO5810, type code 08.C8, software label 409 -- Generated on Tuesday, 09-Aug-16 14:33:27 UTC -- CVS $Id: DVO5810_08c8_sw409.mib,v 1.11 2016/08/09 14:33:29 jvo Exp $ -- -- Copyright 2003-2016 by LYNX Technik AG -- -- These coded instructions, statements, and computer programs contain -- unpublished proprietary information written by LYNX Technik AG and -- are protected by Federal copyright law. They may not be disclosed -- to third parties or copied or duplicated in any form, in whole or -- in part, without the prior written consent of LYNX Technik AG. -- DVO5810-08c8-sw409-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, TimeTicks FROM SNMPv2-SMI -- RFC2578 TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC -- RFC2579 MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF -- RFC2580 mib-modules, products, FixedPointValue1, FixedPointValue2, FixedPointValue3, OnOffValue FROM LYNX-SMI; dvo5810-08c8-sw409 MODULE-IDENTITY LAST-UPDATED "201608091433Z" ORGANIZATION "LYNX Technik AG" CONTACT-INFO "LYNX Technik AG Brunnenweg 3 64331 Weiterstadt http://www.lynx-technik.com mailto:support@lynx-technik.com" DESCRIPTION "MIB module definition for DVO5810, type code 08.C8, software label 409" REVISION "201608091433Z" DESCRIPTION "Generated by LYNX Asset Database" ::= { mib-modules 2248409 } dvo5810-08c8 OBJECT-IDENTITY STATUS current DESCRIPTION "LYNX device type DVO5810" ::= { products 2248 } sw409 OBJECT-IDENTITY STATUS current DESCRIPTION "Software label 409" ::= { dvo5810-08c8 409 } -- Type definitions TypeStatusColor ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { unknown(0), black(1), green(2), yellow(3), red(4) } TypeFactoryReset ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { press(0) } TypeSFPPinning1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { none(0), msa(1), gennum(2) } TypeIn1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { missing(0), sDSDI(1), hDSDI(2), n3GSDI(3), hD3G(4), present(5) } TypeSourceInput1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { electrical(0), optical(1) } TypeEventSDIInput1NoInputSNMP ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { none(0), onOnly(1), offOnly(2), onOff(3) } -- Parameter definitions typeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LYNX product type name" ::= { paramEntry 1 } displayName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name of device (potentially user-defined), as stored in device-controller" ::= { paramEntry 2 } position OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Full-qualified position information (e.g. as used in address-field of remoteIF protocol)" ::= { paramEntry 3 } uptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Connection time of the device to this UI (in seconds)" ::= { paramEntry 4 } type OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device type code" ::= { paramEntry 5 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device version information" ::= { paramEntry 6 } statusColor OBJECT-TYPE SYNTAX TypeStatusColor MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED (red/green/yellow)" ::= { paramEntry 7 } statusColorRGB OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED as #RRGGBB" ::= { paramEntry 8 } statusText OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current status text (OK or error-details)" ::= { paramEntry 9 } factoryReset OBJECT-TYPE SYNTAX TypeFactoryReset MAX-ACCESS read-write STATUS current DESCRIPTION "Reset device to factory default values (set value to PRESS for execution)" ::= { paramEntry 10 } lock OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "Lock Device" ::= { paramEntry 11 } locate OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "toggle the locating function (yellow flashing master LED) ON/OFF" ::= { paramEntry 12 } eventSDIInput1NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Info Event: SDI Input 1 No Input" ::= { paramEntry 14 } inputSignalQuality1Opt OBJECT-TYPE SYNTAX FixedPointValue1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input signal quality 1 (optical)" ::= { paramEntry 15 } sFPModuleType1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "displays the type of detected SFP-Module 1. The SFP part number will also be displayed if SFP-Module is unknown." ::= { paramEntry 16 } sFPModulePartNumber1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the part number of used SFP Module" ::= { paramEntry 17 } sFPPinning1 OBJECT-TYPE SYNTAX TypeSFPPinning1 MAX-ACCESS read-only STATUS current DESCRIPTION "shows pinning of used SFP Module (gennum/msa)" ::= { paramEntry 18 } in1 OBJECT-TYPE SYNTAX TypeIn1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status channel 1" ::= { paramEntry 19 } reclock1 OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "select SDI reclocking on output 1" ::= { paramEntry 20 } sourceInput1 OBJECT-TYPE SYNTAX TypeSourceInput1 MAX-ACCESS read-write STATUS current DESCRIPTION "Select Source for Input 1 from electrical or optical connector" ::= { paramEntry 21 } autoDisableOpticalOutput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "automatically disable (power down) the laser transmitter of the optical output if no valid input signal is connected." ::= { paramEntry 22 } boardID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "BoardID" ::= { paramEntry 23 } eventPrimaryPowermissing OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Info Event: Primary Power missing" ::= { paramEntry 24 } eventRedundantPowermissing OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Info Event: Redundant Power missing" ::= { paramEntry 25 } out1 OBJECT-TYPE SYNTAX TypeIn1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status channel 1" ::= { paramEntry 26 } eventSDIInput1NoInputSNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 1 No Input" ::= { paramEntry 27 } eventPrimaryPowermissingSNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: Primary Power missing" ::= { paramEntry 28 } eventRedundantPowermissingSNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: Redundant Power missing" ::= { paramEntry 29 } sFP1OutPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "displays the average output power of detected SFP-Module 1." ::= { paramEntry 30 } sFP1Wavelength OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "displays the wavelength of detected SFP-Module 1." ::= { paramEntry 31 } sNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Number" ::= { paramEntry 32 } -- Parameter table paramTable OBJECT-TYPE SYNTAX SEQUENCE OF ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of DVO5810 parameters" ::= { sw409 1 } paramEntry OBJECT-TYPE SYNTAX ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of DVO5810 parameters" INDEX { IMPLIED position } ::= { paramTable 1 } ParamEntry ::= SEQUENCE { typeName DisplayString, displayName DisplayString, position OCTET STRING, uptime TimeTicks, type DisplayString, version DisplayString, statusColor TypeStatusColor, statusColorRGB DisplayString, statusText DisplayString, factoryReset TypeFactoryReset, lock OnOffValue, locate OnOffValue, eventSDIInput1NoInput OnOffValue, inputSignalQuality1Opt FixedPointValue1, sFPModuleType1 DisplayString, sFPModulePartNumber1 DisplayString, sFPPinning1 TypeSFPPinning1, in1 TypeIn1, reclock1 OnOffValue, sourceInput1 TypeSourceInput1, autoDisableOpticalOutput OnOffValue, boardID Integer32, eventPrimaryPowermissing OnOffValue, eventRedundantPowermissing OnOffValue, out1 TypeIn1, eventSDIInput1NoInputSNMP TypeEventSDIInput1NoInputSNMP, eventPrimaryPowermissingSNMP TypeEventSDIInput1NoInputSNMP, eventRedundantPowermissingSNMP TypeEventSDIInput1NoInputSNMP, sFP1OutPower DisplayString, sFP1Wavelength DisplayString, sNumber DisplayString } -- Conformance statements conformance OBJECT-IDENTITY STATUS current DESCRIPTION "Conformance declaration of DVO5810" ::= { sw409 2 } paramGroup OBJECT-GROUP OBJECTS { typeName, displayName, position, uptime, type, version, statusColor, statusColorRGB, statusText, factoryReset, lock, locate, eventSDIInput1NoInput, inputSignalQuality1Opt, sFPModuleType1, sFPModulePartNumber1, sFPPinning1, in1, reclock1, sourceInput1, autoDisableOpticalOutput, boardID, eventPrimaryPowermissing, eventRedundantPowermissing, out1, eventSDIInput1NoInputSNMP, eventPrimaryPowermissingSNMP, eventRedundantPowermissingSNMP, sFP1OutPower, sFP1Wavelength, sNumber } STATUS current DESCRIPTION "Conformance group containing all device parameters" ::= { conformance 1 } paramCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance specification" MODULE -- This module MANDATORY-GROUPS { paramGroup } ::= { conformance 2 } END