-- Machine generated MIB file, do not edit! -- -- MIB file for OET1910, type code 42.33, software label 990 -- Generated on Thursday, 08-Apr-21 11:23:17 UTC -- CVS $Id: OET1910_4233_sw990.mib,v 1.2 2021/04/08 11:23:18 til Exp $ -- -- Copyright 2003-2021 by LYNX Technik AG -- -- These coded instructions, statements, and computer programs contain -- unpublished proprietary information written by LYNX Technik AG and -- are protected by Federal copyright law. They may not be disclosed -- to third parties or copied or duplicated in any form, in whole or -- in part, without the prior written consent of LYNX Technik AG. -- OET1910-4233-sw990-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, TimeTicks FROM SNMPv2-SMI -- RFC2578 TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC -- RFC2579 MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF -- RFC2580 mib-modules, products, FixedPointValue1, FixedPointValue2, FixedPointValue3, OnOffValue FROM LYNX-SMI; oet1910-4233-sw990 MODULE-IDENTITY LAST-UPDATED "202104081123Z" ORGANIZATION "LYNX Technik AG" CONTACT-INFO "LYNX Technik AG Brunnenweg 3 64331 Weiterstadt http://www.lynx-technik.com mailto:support@lynx-technik.com" DESCRIPTION "MIB module definition for OET1910, type code 42.33, software label 990" REVISION "202104081123Z" DESCRIPTION "Generated by LYNX Asset Database" ::= { mib-modules 16947990 } oet1910-4233 OBJECT-IDENTITY STATUS current DESCRIPTION "LYNX device type OET1910" ::= { products 16947 } sw990 OBJECT-IDENTITY STATUS current DESCRIPTION "Software label 990" ::= { oet1910-4233 990 } -- Type definitions TypeFactoryReset ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { press(0) } TypeStatusColor ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { off(0), red(1), green(2), yellow(3) } TypeStatusColorRGB ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { n000000(0), ff0000(1), n00ff00(2), ffff00(3) } TypePort1Color ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { off(0), offX(1), green(2), greenX(3) } TypePort1ColorRGB ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { n000000(0), n000000X(1), n00ff00(2), n00ff00X(3) } TypeVariantName ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { oET1910(0), oET1940(1) } TypeLinkStatus1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { unlocked(0), locked(1), negotiated(2) } TypeLinkSpeed1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { n1G(0), n10G(1) } -- Parameter definitions typeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LYNX product type name" ::= { paramEntry 1 } displayName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name of device (potentially user-defined), as stored in device-controller" ::= { paramEntry 2 } position OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Full-qualified position information (e.g. as used in address-field of remoteIF protocol)" ::= { paramEntry 3 } uptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Connection time of the device to this UI (in seconds)" ::= { paramEntry 4 } type OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device type code" ::= { paramEntry 5 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device version information" ::= { paramEntry 6 } factoryReset OBJECT-TYPE SYNTAX TypeFactoryReset MAX-ACCESS read-write STATUS current DESCRIPTION "Reset device to factory default values (set value to PRESS for execution)" ::= { paramEntry 7 } locate OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "toggle the locating function (yellow flashing master LED) ON/OFF" ::= { paramEntry 8 } statusColor OBJECT-TYPE SYNTAX TypeStatusColor MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED (red/green/yellow)" ::= { paramEntry 9 } statusColorRGB OBJECT-TYPE SYNTAX TypeStatusColorRGB MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED as #RRGGBB" ::= { paramEntry 10 } port1Color OBJECT-TYPE SYNTAX TypePort1Color MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Port 1 LED (off/green)" ::= { paramEntry 11 } port1ColorRGB OBJECT-TYPE SYNTAX TypePort1ColorRGB MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Port 1 LED as #RRGGBB" ::= { paramEntry 12 } port2Color OBJECT-TYPE SYNTAX TypePort1Color MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Port 2 LED (off/green)" ::= { paramEntry 13 } port2ColorRGB OBJECT-TYPE SYNTAX TypePort1ColorRGB MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Port 2 LED as #RRGGBB" ::= { paramEntry 14 } variantName OBJECT-TYPE SYNTAX TypeVariantName MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Variant of this Device" ::= { paramEntry 16 } linkStatus1 OBJECT-TYPE SYNTAX TypeLinkStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the status of Link 1" ::= { paramEntry 17 } linkSpeed1 OBJECT-TYPE SYNTAX TypeLinkSpeed1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the speed of Link 1" ::= { paramEntry 18 } sFPModulePartNumber1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the part number of detected SFP Module 1" ::= { paramEntry 19 } sFPModuleType1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the type of detected SFP-Module 1. The SFP part number will be displayed if SFP Module is unknown." ::= { paramEntry 20 } inputBudgetOpt1 OBJECT-TYPE SYNTAX FixedPointValue1 MAX-ACCESS read-only STATUS current DESCRIPTION "Displays input budget on opical port 1" ::= { paramEntry 21 } linkStatus2 OBJECT-TYPE SYNTAX TypeLinkStatus1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the status of Link 2" ::= { paramEntry 22 } linkSpeed2 OBJECT-TYPE SYNTAX TypeLinkSpeed1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the speed of Link 2" ::= { paramEntry 23 } sFPModulePartNumber2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the part number of detected SFP Module 2" ::= { paramEntry 24 } sFPModuleType2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the type of detected SFP-Module 2. The SFP part number will be displayed if SFP Module is unknown." ::= { paramEntry 25 } inputBudgetOpt2 OBJECT-TYPE SYNTAX FixedPointValue1 MAX-ACCESS read-only STATUS current DESCRIPTION "Displays input budget on opical port 2" ::= { paramEntry 26 } -- Parameter table paramTable OBJECT-TYPE SYNTAX SEQUENCE OF ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of OET1910 parameters" ::= { sw990 1 } paramEntry OBJECT-TYPE SYNTAX ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of OET1910 parameters" INDEX { IMPLIED position } ::= { paramTable 1 } ParamEntry ::= SEQUENCE { typeName DisplayString, displayName DisplayString, position OCTET STRING, uptime TimeTicks, type DisplayString, version DisplayString, factoryReset TypeFactoryReset, locate OnOffValue, statusColor TypeStatusColor, statusColorRGB TypeStatusColorRGB, port1Color TypePort1Color, port1ColorRGB TypePort1ColorRGB, port2Color TypePort1Color, port2ColorRGB TypePort1ColorRGB, variantName TypeVariantName, linkStatus1 TypeLinkStatus1, linkSpeed1 TypeLinkSpeed1, sFPModulePartNumber1 DisplayString, sFPModuleType1 DisplayString, inputBudgetOpt1 FixedPointValue1, linkStatus2 TypeLinkStatus1, linkSpeed2 TypeLinkSpeed1, sFPModulePartNumber2 DisplayString, sFPModuleType2 DisplayString, inputBudgetOpt2 FixedPointValue1 } -- Conformance statements conformance OBJECT-IDENTITY STATUS current DESCRIPTION "Conformance declaration of OET1910" ::= { sw990 2 } paramGroup OBJECT-GROUP OBJECTS { typeName, displayName, position, uptime, type, version, factoryReset, locate, statusColor, statusColorRGB, port1Color, port1ColorRGB, port2Color, port2ColorRGB, variantName, linkStatus1, linkSpeed1, sFPModulePartNumber1, sFPModuleType1, inputBudgetOpt1, linkStatus2, linkSpeed2, sFPModulePartNumber2, sFPModuleType2, inputBudgetOpt2 } STATUS current DESCRIPTION "Conformance group containing all device parameters" ::= { conformance 1 } paramCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance specification" MODULE -- This module MANDATORY-GROUPS { paramGroup } ::= { conformance 2 } END