-- Machine generated MIB file, do not edit! -- -- MIB file for OTR5842, type code 08.D7, software label 515 -- Generated on Tuesday, 09-Aug-16 14:41:56 UTC -- CVS $Id: OTR5842_08d7_sw515.mib,v 1.6 2016/08/09 14:41:58 jvo Exp $ -- -- Copyright 2003-2016 by LYNX Technik AG -- -- These coded instructions, statements, and computer programs contain -- unpublished proprietary information written by LYNX Technik AG and -- are protected by Federal copyright law. They may not be disclosed -- to third parties or copied or duplicated in any form, in whole or -- in part, without the prior written consent of LYNX Technik AG. -- OTR5842-08d7-sw515-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, TimeTicks FROM SNMPv2-SMI -- RFC2578 TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC -- RFC2579 MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF -- RFC2580 mib-modules, products, FixedPointValue1, FixedPointValue2, FixedPointValue3, OnOffValue FROM LYNX-SMI; otr5842-08d7-sw515 MODULE-IDENTITY LAST-UPDATED "201608091441Z" ORGANIZATION "LYNX Technik AG" CONTACT-INFO "LYNX Technik AG Brunnenweg 3 64331 Weiterstadt http://www.lynx-technik.com mailto:support@lynx-technik.com" DESCRIPTION "MIB module definition for OTR5842, type code 08.D7, software label 515" REVISION "201608091441Z" DESCRIPTION "Generated by LYNX Asset Database" ::= { mib-modules 2263515 } otr5842-08d7 OBJECT-IDENTITY STATUS current DESCRIPTION "LYNX device type OTR5842" ::= { products 2263 } sw515 OBJECT-IDENTITY STATUS current DESCRIPTION "Software label 515" ::= { otr5842-08d7 515 } -- Type definitions TypeStatusColor ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { unknown(0), black(1), green(2), yellow(3), red(4) } TypeFactoryReset ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { press(0) } TypeSourceInput1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { optical(0), electrical(1) } TypeIn1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { missing(0), sDSDI(1), hDSDI(2), n3GSDI(3), hD3G(4), present(5) } TypeSourceOut1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { in1(0), in2(1), in3(2), in4(3) } TypeEventSDIInput1NoInputSNMP ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { none(0), onOnly(1), offOnly(2), onOff(3) } -- Parameter definitions typeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LYNX product type name" ::= { paramEntry 1 } displayName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name of device (potentially user-defined), as stored in device-controller" ::= { paramEntry 2 } position OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Full-qualified position information (e.g. as used in address-field of remoteIF protocol)" ::= { paramEntry 3 } uptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Connection time of the device to this UI (in seconds)" ::= { paramEntry 4 } type OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device type code" ::= { paramEntry 5 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device version information" ::= { paramEntry 6 } statusColor OBJECT-TYPE SYNTAX TypeStatusColor MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED (red/green/yellow)" ::= { paramEntry 7 } statusColorRGB OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED as #RRGGBB" ::= { paramEntry 8 } statusText OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current status text (OK or error-details)" ::= { paramEntry 9 } factoryReset OBJECT-TYPE SYNTAX TypeFactoryReset MAX-ACCESS read-write STATUS current DESCRIPTION "Reset device to factory default values (set value to PRESS for execution)" ::= { paramEntry 10 } lock OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "Lock Device" ::= { paramEntry 11 } locate OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "toggle the locating function (yellow flashing master LED) ON/OFF" ::= { paramEntry 12 } eventSDIInput1NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Info Event: SDI Input 1 No Input" ::= { paramEntry 14 } eventSDIInput2NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Info Event: SDI Input 2 No Input" ::= { paramEntry 15 } eventSDIInput3NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Info Event: SDI Input 3 No Input" ::= { paramEntry 16 } eventSDIInput4NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Info Event: SDI Input 4 No Input" ::= { paramEntry 17 } eventPSU1Failure OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "PSU1: Failure" ::= { paramEntry 18 } eventPSU2Failure OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "PSU2: Failure" ::= { paramEntry 19 } sourceInput1 OBJECT-TYPE SYNTAX TypeSourceInput1 MAX-ACCESS read-write STATUS current DESCRIPTION "Select Source for Input 1 from electrical or optical connector" ::= { paramEntry 20 } sourceInput2 OBJECT-TYPE SYNTAX TypeSourceInput1 MAX-ACCESS read-write STATUS current DESCRIPTION "Select Source for Input 2 from electrical or optical connector" ::= { paramEntry 21 } in1 OBJECT-TYPE SYNTAX TypeIn1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status channel 1" ::= { paramEntry 22 } in2 OBJECT-TYPE SYNTAX TypeIn1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status channel 2" ::= { paramEntry 23 } in3 OBJECT-TYPE SYNTAX TypeIn1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status channel 3" ::= { paramEntry 24 } in4 OBJECT-TYPE SYNTAX TypeIn1 MAX-ACCESS read-only STATUS current DESCRIPTION "Input status channel 4" ::= { paramEntry 25 } reclock1 OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "select SDI reclocking on input 1" ::= { paramEntry 26 } reclock2 OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "select SDI reclocking on input 2" ::= { paramEntry 27 } reclock3 OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "select SDI reclocking on input 3" ::= { paramEntry 28 } reclock4 OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "select SDI reclocking on input 4" ::= { paramEntry 29 } input1OpticalSignalQuality OBJECT-TYPE SYNTAX FixedPointValue1 MAX-ACCESS read-only STATUS current DESCRIPTION "Signal quality at optical SDI Input 1" ::= { paramEntry 30 } input2OpticalSignalQuality OBJECT-TYPE SYNTAX FixedPointValue1 MAX-ACCESS read-only STATUS current DESCRIPTION "Signal quality at optical SDI Input 2" ::= { paramEntry 31 } sFPModuleType1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "displays the type of detected SFP-Module 1. The SFP part number will also be displayed if SFP-Module is unknown." ::= { paramEntry 32 } sFPModulePartNumber1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the part number of used SFP Module" ::= { paramEntry 33 } sFPModuleType2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "displays the type of detected SFP-Module 2. The SFP part number will also be displayed if SFP-Module is unknown." ::= { paramEntry 34 } sFPModulePartNumber2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the part number of used SFP Module" ::= { paramEntry 35 } sourceOut1 OBJECT-TYPE SYNTAX TypeSourceOut1 MAX-ACCESS read-write STATUS current DESCRIPTION "Select Source stream for output 1 from input 1 or 2" ::= { paramEntry 36 } sourceOut2 OBJECT-TYPE SYNTAX TypeSourceOut1 MAX-ACCESS read-write STATUS current DESCRIPTION "Select Source stream for output 2 from input 1 or 2" ::= { paramEntry 37 } sourceOut3 OBJECT-TYPE SYNTAX TypeSourceOut1 MAX-ACCESS read-write STATUS current DESCRIPTION "Select Source stream for output 3 from input 1 or 2" ::= { paramEntry 38 } sourceOut4 OBJECT-TYPE SYNTAX TypeSourceOut1 MAX-ACCESS read-write STATUS current DESCRIPTION "Select Source stream for output 4 from input 1 or 2" ::= { paramEntry 39 } autoDisableOpticalOutput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "automatically disable (power down) the laser transmitter of the optical output if no valid input signal is connected." ::= { paramEntry 40 } eventPrimaryPowermissing OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Info Event: Primary Power missing" ::= { paramEntry 41 } eventRedundantPowermissing OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Info Event: Redundant Power missing" ::= { paramEntry 42 } boardID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "BoardID" ::= { paramEntry 43 } out1 OBJECT-TYPE SYNTAX TypeIn1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status channel 1" ::= { paramEntry 44 } out2 OBJECT-TYPE SYNTAX TypeIn1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status channel 2" ::= { paramEntry 45 } out3 OBJECT-TYPE SYNTAX TypeIn1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status channel 3" ::= { paramEntry 46 } out4 OBJECT-TYPE SYNTAX TypeIn1 MAX-ACCESS read-only STATUS current DESCRIPTION "Output status channel 4" ::= { paramEntry 47 } eventSDIInput1NoInputSNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 1 No Input" ::= { paramEntry 48 } eventSDIInput2NoInputSNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 2 No Input" ::= { paramEntry 49 } eventSDIInput3NoInputSNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 3 No Input" ::= { paramEntry 50 } eventSDIInput4NoInputSNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 4 No Input" ::= { paramEntry 51 } eventPrimaryPowermissingSNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: Primary Power missing" ::= { paramEntry 52 } eventRedundantPowermissingSNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: Redundant Power missing" ::= { paramEntry 53 } sFP1OutPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "displays the average output power of detected SFP-Module 1." ::= { paramEntry 54 } sFP1Wavelength1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "displays the wavelength of detected SFP-Module 1." ::= { paramEntry 55 } sFP1Wavelength2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "displays the wavelength of detected SFP-Module 1." ::= { paramEntry 56 } sFP2OutPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "displays the average output power of detected SFP-Module 2." ::= { paramEntry 57 } sFP2Wavelength1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "displays the wavelength of detected SFP-Module 2." ::= { paramEntry 58 } sFP2Wavelength2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "displays the wavelength of detected SFP-Module 2." ::= { paramEntry 59 } sNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Number" ::= { paramEntry 60 } -- Parameter table paramTable OBJECT-TYPE SYNTAX SEQUENCE OF ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of OTR5842 parameters" ::= { sw515 1 } paramEntry OBJECT-TYPE SYNTAX ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of OTR5842 parameters" INDEX { IMPLIED position } ::= { paramTable 1 } ParamEntry ::= SEQUENCE { typeName DisplayString, displayName DisplayString, position OCTET STRING, uptime TimeTicks, type DisplayString, version DisplayString, statusColor TypeStatusColor, statusColorRGB DisplayString, statusText DisplayString, factoryReset TypeFactoryReset, lock OnOffValue, locate OnOffValue, eventSDIInput1NoInput OnOffValue, eventSDIInput2NoInput OnOffValue, eventSDIInput3NoInput OnOffValue, eventSDIInput4NoInput OnOffValue, eventPSU1Failure OnOffValue, eventPSU2Failure OnOffValue, sourceInput1 TypeSourceInput1, sourceInput2 TypeSourceInput1, in1 TypeIn1, in2 TypeIn1, in3 TypeIn1, in4 TypeIn1, reclock1 OnOffValue, reclock2 OnOffValue, reclock3 OnOffValue, reclock4 OnOffValue, input1OpticalSignalQuality FixedPointValue1, input2OpticalSignalQuality FixedPointValue1, sFPModuleType1 DisplayString, sFPModulePartNumber1 DisplayString, sFPModuleType2 DisplayString, sFPModulePartNumber2 DisplayString, sourceOut1 TypeSourceOut1, sourceOut2 TypeSourceOut1, sourceOut3 TypeSourceOut1, sourceOut4 TypeSourceOut1, autoDisableOpticalOutput OnOffValue, eventPrimaryPowermissing OnOffValue, eventRedundantPowermissing OnOffValue, boardID Integer32, out1 TypeIn1, out2 TypeIn1, out3 TypeIn1, out4 TypeIn1, eventSDIInput1NoInputSNMP TypeEventSDIInput1NoInputSNMP, eventSDIInput2NoInputSNMP TypeEventSDIInput1NoInputSNMP, eventSDIInput3NoInputSNMP TypeEventSDIInput1NoInputSNMP, eventSDIInput4NoInputSNMP TypeEventSDIInput1NoInputSNMP, eventPrimaryPowermissingSNMP TypeEventSDIInput1NoInputSNMP, eventRedundantPowermissingSNMP TypeEventSDIInput1NoInputSNMP, sFP1OutPower DisplayString, sFP1Wavelength1 DisplayString, sFP1Wavelength2 DisplayString, sFP2OutPower DisplayString, sFP2Wavelength1 DisplayString, sFP2Wavelength2 DisplayString, sNumber DisplayString } -- Conformance statements conformance OBJECT-IDENTITY STATUS current DESCRIPTION "Conformance declaration of OTR5842" ::= { sw515 2 } paramGroup OBJECT-GROUP OBJECTS { typeName, displayName, position, uptime, type, version, statusColor, statusColorRGB, statusText, factoryReset, lock, locate, eventSDIInput1NoInput, eventSDIInput2NoInput, eventSDIInput3NoInput, eventSDIInput4NoInput, eventPSU1Failure, eventPSU2Failure, sourceInput1, sourceInput2, in1, in2, in3, in4, reclock1, reclock2, reclock3, reclock4, input1OpticalSignalQuality, input2OpticalSignalQuality, sFPModuleType1, sFPModulePartNumber1, sFPModuleType2, sFPModulePartNumber2, sourceOut1, sourceOut2, sourceOut3, sourceOut4, autoDisableOpticalOutput, eventPrimaryPowermissing, eventRedundantPowermissing, boardID, out1, out2, out3, out4, eventSDIInput1NoInputSNMP, eventSDIInput2NoInputSNMP, eventSDIInput3NoInputSNMP, eventSDIInput4NoInputSNMP, eventPrimaryPowermissingSNMP, eventRedundantPowermissingSNMP, sFP1OutPower, sFP1Wavelength1, sFP1Wavelength2, sFP2OutPower, sFP2Wavelength1, sFP2Wavelength2, sNumber } STATUS current DESCRIPTION "Conformance group containing all device parameters" ::= { conformance 1 } paramCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance specification" MODULE -- This module MANDATORY-GROUPS { paramGroup } ::= { conformance 2 } END