-- Machine generated MIB file, do not edit! -- -- MIB file for OTT1814, type code 42.59, software label 1308 -- Generated on Friday, 05-Dec-25 13:01:27 CET -- -- Copyright 2003-2025 by LYNX Technik AG -- -- These coded instructions, statements, and computer programs contain -- unpublished proprietary information written by LYNX Technik AG and -- are protected by Federal copyright law. They may not be disclosed -- to third parties or copied or duplicated in any form, in whole or -- in part, without the prior written consent of LYNX Technik AG. -- OTT1814-4259-sw1308-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, TimeTicks FROM SNMPv2-SMI -- RFC2578 TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC -- RFC2579 MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF -- RFC2580 mib-modules, products, FixedPointValue1, FixedPointValue2, FixedPointValue3, OnOffValue FROM LYNX-SMI; ott1814-4259-sw1308 MODULE-IDENTITY LAST-UPDATED "202512051201Z" ORGANIZATION "LYNX Technik AG" CONTACT-INFO "LYNX Technik AG Brunnenweg 3 64331 Weiterstadt http://www.lynx-technik.com mailto:support@lynx-technik.com" DESCRIPTION "MIB module definition for OTT1814, type code 42.59, software label 1308" REVISION "202512051201Z" DESCRIPTION "Generated by LYNX Asset Database" ::= { mib-modules 16986308 } ott1814-4259 OBJECT-IDENTITY STATUS current DESCRIPTION "LYNX device type OTT1814" ::= { products 16985 } sw1308 OBJECT-IDENTITY STATUS current DESCRIPTION "Software label 1308" ::= { ott1814-4259 1308 } -- Type definitions TypeFactoryReset ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { press(0) } TypeStatusColor ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { off(0), red(1), green(2), yellow(3) } TypeStatusColorRGB ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { n000000(0), ff0000(1), n00ff00(2), ffff00(3) } TypeBoardVariant ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { a(0), b(1), c(2) } TypeVariantName ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { invalid(0), invalidX(1), invalidXX(2), invalidXXX(3), invalidXXXX(4), invalidXXXXX(5), invalidXXXXXX(6), invalidXXXXXXX(7), invalidXXXXXXXX(8), oTR1414(9), oBD1414(10), oTR1814(11), oBD1814(12), oTT1414(13), oTT1814(14), oRR1404(15), oRR1804(16) } TypeInputStatusBNC1 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { missing(0), n125Mbps(1), n270Mbps(2), n15Gbps(3), n3Gbps(4), n6Gbps(5), n12Gbps(6), disabled(7) } -- Parameter definitions typeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LYNX product type name" ::= { paramEntry 1 } displayName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name of device (potentially user-defined), as stored in device-controller" ::= { paramEntry 2 } position OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Full-qualified position information (e.g. as used in address-field of remoteIF protocol)" ::= { paramEntry 3 } uptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Connection time of the device to this UI (in seconds)" ::= { paramEntry 4 } type OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device type code" ::= { paramEntry 5 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device version information" ::= { paramEntry 6 } factoryReset OBJECT-TYPE SYNTAX TypeFactoryReset MAX-ACCESS read-write STATUS current DESCRIPTION "Reset device to factory default values (set value to PRESS for execution)" ::= { paramEntry 7 } locate OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "toggle the locating function (yellow flashing master LED) ON/OFF" ::= { paramEntry 8 } statusColor OBJECT-TYPE SYNTAX TypeStatusColor MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED (red/green/yellow)" ::= { paramEntry 9 } statusColorRGB OBJECT-TYPE SYNTAX TypeStatusColorRGB MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED as #RRGGBB" ::= { paramEntry 10 } boardVariant OBJECT-TYPE SYNTAX TypeBoardVariant MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Variant of the Board" ::= { paramEntry 12 } variantName OBJECT-TYPE SYNTAX TypeVariantName MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Variant of this Device" ::= { paramEntry 13 } sFPModulePartNumber1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the part number of detected SFP Module 1" ::= { paramEntry 14 } sFPModuleType1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the type of detected SFP-Module 1. The SFP part number will be displayed if SFP Module is unknown." ::= { paramEntry 15 } sFPModulePartNumber2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the part number of detected SFP Module 2" ::= { paramEntry 16 } sFPModuleType2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the type of detected SFP-Module 2. The SFP part number will be displayed if SFP Module is unknown." ::= { paramEntry 17 } inputStatusBNC1 OBJECT-TYPE SYNTAX TypeInputStatusBNC1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Signal Rate of BNC Input 1" ::= { paramEntry 18 } outputStatusOpt1 OBJECT-TYPE SYNTAX TypeInputStatusBNC1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Signal Rate of Optical Output 1" ::= { paramEntry 19 } inputStatusBNC2 OBJECT-TYPE SYNTAX TypeInputStatusBNC1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Signal Rate of BNC Input 2" ::= { paramEntry 20 } outputStatusOpt2 OBJECT-TYPE SYNTAX TypeInputStatusBNC1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Signal Rate of Optical Output 2" ::= { paramEntry 21 } inputStatusBNC3 OBJECT-TYPE SYNTAX TypeInputStatusBNC1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Signal Rate of BNC Input 3" ::= { paramEntry 22 } outputStatusOpt3 OBJECT-TYPE SYNTAX TypeInputStatusBNC1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Signal Rate of Optical Output 3" ::= { paramEntry 23 } inputStatusBNC4 OBJECT-TYPE SYNTAX TypeInputStatusBNC1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Signal Rate of BNC Input 4" ::= { paramEntry 24 } outputStatusOpt4 OBJECT-TYPE SYNTAX TypeInputStatusBNC1 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Signal Rate of Optical Output 4" ::= { paramEntry 25 } -- Parameter table paramTable OBJECT-TYPE SYNTAX SEQUENCE OF ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of OTT1814 parameters" ::= { sw1308 1 } paramEntry OBJECT-TYPE SYNTAX ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of OTT1814 parameters" INDEX { IMPLIED position } ::= { paramTable 1 } ParamEntry ::= SEQUENCE { typeName DisplayString, displayName DisplayString, position OCTET STRING, uptime TimeTicks, type DisplayString, version DisplayString, factoryReset TypeFactoryReset, locate OnOffValue, statusColor TypeStatusColor, statusColorRGB TypeStatusColorRGB, boardVariant TypeBoardVariant, variantName TypeVariantName, sFPModulePartNumber1 DisplayString, sFPModuleType1 DisplayString, sFPModulePartNumber2 DisplayString, sFPModuleType2 DisplayString, inputStatusBNC1 TypeInputStatusBNC1, outputStatusOpt1 TypeInputStatusBNC1, inputStatusBNC2 TypeInputStatusBNC1, outputStatusOpt2 TypeInputStatusBNC1, inputStatusBNC3 TypeInputStatusBNC1, outputStatusOpt3 TypeInputStatusBNC1, inputStatusBNC4 TypeInputStatusBNC1, outputStatusOpt4 TypeInputStatusBNC1 } -- Conformance statements conformance OBJECT-IDENTITY STATUS current DESCRIPTION "Conformance declaration of OTT1814" ::= { sw1308 2 } paramGroup OBJECT-GROUP OBJECTS { typeName, displayName, position, uptime, type, version, factoryReset, locate, statusColor, statusColorRGB, boardVariant, variantName, sFPModulePartNumber1, sFPModuleType1, sFPModulePartNumber2, sFPModuleType2, inputStatusBNC1, outputStatusOpt1, inputStatusBNC2, outputStatusOpt2, inputStatusBNC3, outputStatusOpt3, inputStatusBNC4, outputStatusOpt4 } STATUS current DESCRIPTION "Conformance group containing all device parameters" ::= { conformance 1 } paramCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance specification" MODULE -- This module MANDATORY-GROUPS { paramGroup } ::= { conformance 2 } END