-- Machine generated MIB file, do not edit! -- -- MIB file for RCT5023-GS, type code C2.09, software label 544 -- Generated on Tuesday, 09-Aug-16 16:28:24 UTC -- CVS $Id: RCT5023-GS_c209_sw544.mib,v 1.6 2016/08/09 16:28:25 jvo Exp $ -- -- Copyright 2003-2016 by LYNX Technik AG -- -- These coded instructions, statements, and computer programs contain -- unpublished proprietary information written by LYNX Technik AG and -- are protected by Federal copyright law. They may not be disclosed -- to third parties or copied or duplicated in any form, in whole or -- in part, without the prior written consent of LYNX Technik AG. -- RCT5023-GS-c209-sw544-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, TimeTicks FROM SNMPv2-SMI -- RFC2578 TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC -- RFC2579 MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF -- RFC2580 mib-modules, products, FixedPointValue1, FixedPointValue2, FixedPointValue3, OnOffValue FROM LYNX-SMI; rct5023-gs-c209-sw544 MODULE-IDENTITY LAST-UPDATED "201608091628Z" ORGANIZATION "LYNX Technik AG" CONTACT-INFO "LYNX Technik AG Brunnenweg 3 64331 Weiterstadt http://www.lynx-technik.com mailto:support@lynx-technik.com" DESCRIPTION "MIB module definition for RCT5023-GS, type code C2.09, software label 544" REVISION "201608091628Z" DESCRIPTION "Generated by LYNX Asset Database" ::= { mib-modules 49673544 } rct5023-gs-c209 OBJECT-IDENTITY STATUS current DESCRIPTION "LYNX device type RCT5023-GS" ::= { products 49673 } sw544 OBJECT-IDENTITY STATUS current DESCRIPTION "Software label 544" ::= { rct5023-gs-c209 544 } -- Type definitions TypeStatusColor ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { unknown(0), black(1), green(2), yellow(3), red(4) } TypeFactoryReset ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { press(0) } TypeRackType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { series3000(0), series5000(1) } TypeFan1Status ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { ok(0), fail(1), missing(2) } TypeAlarmTemp ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { none(0), minor(1), major(2) } -- Parameter definitions typeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LYNX product type name" ::= { paramEntry 1 } displayName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name of device (potentially user-defined), as stored in device-controller" ::= { paramEntry 2 } position OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Full-qualified position information (e.g. as used in address-field of remoteIF protocol)" ::= { paramEntry 3 } uptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Connection time of the device to this UI (in seconds)" ::= { paramEntry 4 } type OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device type code" ::= { paramEntry 5 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device version information" ::= { paramEntry 6 } statusColor OBJECT-TYPE SYNTAX TypeStatusColor MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED (red/green/yellow)" ::= { paramEntry 7 } statusColorRGB OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED as #RRGGBB" ::= { paramEntry 8 } statusText OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current status text (OK or error-details)" ::= { paramEntry 9 } factoryReset OBJECT-TYPE SYNTAX TypeFactoryReset MAX-ACCESS read-write STATUS current DESCRIPTION "Reset device to factory default values (set value to PRESS for execution)" ::= { paramEntry 10 } lock OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "Lock Device" ::= { paramEntry 11 } locate OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "toggle the locating function (yellow flashing master LED) ON/OFF" ::= { paramEntry 12 } rackType OBJECT-TYPE SYNTAX TypeRackType MAX-ACCESS read-only STATUS current DESCRIPTION "Type of rack that this controller board is running in (Series 3000/5000)" ::= { paramEntry 14 } gPO1Status OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the GPO (General Purpose Output) contact 1 on the back of the rack (Minor Alarm)" ::= { paramEntry 15 } gPO2Status OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the GPO (General Purpose Output) contact 2 on the back of the rack (Major Alarm)" ::= { paramEntry 16 } gPIStatus OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the GPI (General Purpose Input) contact on the back of the Rack (on/off)" ::= { paramEntry 17 } pSU1TypeAndVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Type name of power supply unit" ::= { paramEntry 18 } pSU1Status OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status of power supply unit" ::= { paramEntry 19 } pSU1Voltage OBJECT-TYPE SYNTAX FixedPointValue1 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage of power supply unit" ::= { paramEntry 20 } pSU1Temperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of power supply unit" ::= { paramEntry 21 } pSU2TypeAndVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Type name of power supply unit" ::= { paramEntry 22 } pSU2Status OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status of power supply unit" ::= { paramEntry 23 } pSU2Voltage OBJECT-TYPE SYNTAX FixedPointValue1 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage of power supply unit" ::= { paramEntry 24 } pSU2Temperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of power supply unit" ::= { paramEntry 25 } slotStatus1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 1: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 26 } slotStatus2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 2: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 27 } slotStatus3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 3: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 28 } slotStatus4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 4: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 29 } slotStatus5 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 5: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 30 } slotStatus6 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 6: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 31 } slotStatus7 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 7: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 32 } slotStatus8 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 8: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 33 } slotStatus9 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 9: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 34 } slotStatus10 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 10: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 35 } slotStatusPSU1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status PSU 1: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 36 } slotStatusPSU2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status PSU 2: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 37 } slotStatusFan1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status Fan 1: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 38 } slotStatusFan2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status Fan 2: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 39 } slotStatusFan3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status Fan 3: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 40 } fan1Status OBJECT-TYPE SYNTAX TypeFan1Status MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of fan 1" ::= { paramEntry 41 } fan2Status OBJECT-TYPE SYNTAX TypeFan1Status MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of fan 2" ::= { paramEntry 42 } fan3Status OBJECT-TYPE SYNTAX TypeFan1Status MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of fan 3" ::= { paramEntry 43 } alarmTemp OBJECT-TYPE SYNTAX TypeAlarmTemp MAX-ACCESS read-write STATUS current DESCRIPTION "Specify whether a High Temperature event shall trigger a Major or Minor Alarm (GPO contact) or none of the above." ::= { paramEntry 44 } alarmVolt OBJECT-TYPE SYNTAX TypeAlarmTemp MAX-ACCESS read-write STATUS current DESCRIPTION "Specify whether a Voltage out of range event shall trigger a Major or Minor Alarm (GPO contact) or none of the above." ::= { paramEntry 45 } alarmRPS1 OBJECT-TYPE SYNTAX TypeAlarmTemp MAX-ACCESS read-write STATUS current DESCRIPTION "Specify whether a One RPS missing event shall trigger a Major or Minor Alarm (GPO contact) or none of the above." ::= { paramEntry 46 } alarmFanFail OBJECT-TYPE SYNTAX TypeAlarmTemp MAX-ACCESS read-write STATUS current DESCRIPTION "Specify whether a Fan Failure event shall trigger a Major or Minor Alarm (GPO contact) or none of the above." ::= { paramEntry 47 } alarmFanLost OBJECT-TYPE SYNTAX TypeAlarmTemp MAX-ACCESS read-write STATUS current DESCRIPTION "Specify whether a Front Panel Fan missing event shall trigger a Major or Minor Alarm (GPO contact) or none of the above." ::= { paramEntry 48 } hotsync OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "HotSync adds data security as a reliable and automatic recovery mechanism for configuration data of individual processing devices.
HotSync is enabled as a function of a RackController and applies to all devices in the controllers stack, i.e. in the local RackFrame and in connected Extensions, if any.
When enabled, HotSync automatically maintains a dynamic copy of the current configuration for all devices. The backup copy is stored inside the controller. You can think of this mechanism as if a backup copy of the device-settings were stored in the slot.
If you ever have to replace a processing board, and you bring a new device of the same type into the same slot, then HotSync will automatically copy the last valid settings from the controllers backup-memory into the new board" ::= { paramEntry 49 } sNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Number" ::= { paramEntry 77 } -- Parameter table paramTable OBJECT-TYPE SYNTAX SEQUENCE OF ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of RCT5023-GS parameters" ::= { sw544 1 } paramEntry OBJECT-TYPE SYNTAX ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of RCT5023-GS parameters" INDEX { IMPLIED position } ::= { paramTable 1 } ParamEntry ::= SEQUENCE { typeName DisplayString, displayName DisplayString, position OCTET STRING, uptime TimeTicks, type DisplayString, version DisplayString, statusColor TypeStatusColor, statusColorRGB DisplayString, statusText DisplayString, factoryReset TypeFactoryReset, lock OnOffValue, locate OnOffValue, rackType TypeRackType, gPO1Status OnOffValue, gPO2Status OnOffValue, gPIStatus OnOffValue, pSU1TypeAndVersion DisplayString, pSU1Status DisplayString, pSU1Voltage FixedPointValue1, pSU1Temperature Integer32, pSU2TypeAndVersion DisplayString, pSU2Status DisplayString, pSU2Voltage FixedPointValue1, pSU2Temperature Integer32, slotStatus1 DisplayString, slotStatus2 DisplayString, slotStatus3 DisplayString, slotStatus4 DisplayString, slotStatus5 DisplayString, slotStatus6 DisplayString, slotStatus7 DisplayString, slotStatus8 DisplayString, slotStatus9 DisplayString, slotStatus10 DisplayString, slotStatusPSU1 DisplayString, slotStatusPSU2 DisplayString, slotStatusFan1 DisplayString, slotStatusFan2 DisplayString, slotStatusFan3 DisplayString, fan1Status TypeFan1Status, fan2Status TypeFan1Status, fan3Status TypeFan1Status, alarmTemp TypeAlarmTemp, alarmVolt TypeAlarmTemp, alarmRPS1 TypeAlarmTemp, alarmFanFail TypeAlarmTemp, alarmFanLost TypeAlarmTemp, hotsync OnOffValue, sNumber DisplayString } -- Conformance statements conformance OBJECT-IDENTITY STATUS current DESCRIPTION "Conformance declaration of RCT5023-GS" ::= { sw544 2 } paramGroup OBJECT-GROUP OBJECTS { typeName, displayName, position, uptime, type, version, statusColor, statusColorRGB, statusText, factoryReset, lock, locate, rackType, gPO1Status, gPO2Status, gPIStatus, pSU1TypeAndVersion, pSU1Status, pSU1Voltage, pSU1Temperature, pSU2TypeAndVersion, pSU2Status, pSU2Voltage, pSU2Temperature, slotStatus1, slotStatus2, slotStatus3, slotStatus4, slotStatus5, slotStatus6, slotStatus7, slotStatus8, slotStatus9, slotStatus10, slotStatusPSU1, slotStatusPSU2, slotStatusFan1, slotStatusFan2, slotStatusFan3, fan1Status, fan2Status, fan3Status, alarmTemp, alarmVolt, alarmRPS1, alarmFanFail, alarmFanLost, hotsync, sNumber } STATUS current DESCRIPTION "Conformance group containing all device parameters" ::= { conformance 1 } paramCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance specification" MODULE -- This module MANDATORY-GROUPS { paramGroup } ::= { conformance 2 } END