-- Machine generated MIB file, do not edit! -- -- MIB file for RFR5041, type code C2.05, software label 393 -- Generated on Tuesday, 09-Aug-16 16:24:13 UTC -- CVS $Id: RFR5041_c205_sw393.mib,v 1.9 2016/08/09 16:24:14 jvo Exp $ -- -- Copyright 2003-2016 by LYNX Technik AG -- -- These coded instructions, statements, and computer programs contain -- unpublished proprietary information written by LYNX Technik AG and -- are protected by Federal copyright law. They may not be disclosed -- to third parties or copied or duplicated in any form, in whole or -- in part, without the prior written consent of LYNX Technik AG. -- RFR5041-c205-sw393-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, TimeTicks FROM SNMPv2-SMI -- RFC2578 TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC -- RFC2579 MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF -- RFC2580 mib-modules, products, FixedPointValue1, FixedPointValue2, FixedPointValue3, OnOffValue FROM LYNX-SMI; rfr5041-c205-sw393 MODULE-IDENTITY LAST-UPDATED "201608091624Z" ORGANIZATION "LYNX Technik AG" CONTACT-INFO "LYNX Technik AG Brunnenweg 3 64331 Weiterstadt http://www.lynx-technik.com mailto:support@lynx-technik.com" DESCRIPTION "MIB module definition for RFR5041, type code C2.05, software label 393" REVISION "201608091624Z" DESCRIPTION "Generated by LYNX Asset Database" ::= { mib-modules 49669393 } rfr5041-c205 OBJECT-IDENTITY STATUS current DESCRIPTION "LYNX device type RFR5041" ::= { products 49669 } sw393 OBJECT-IDENTITY STATUS current DESCRIPTION "Software label 393" ::= { rfr5041-c205 393 } -- Type definitions TypeStatusColor ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { unknown(0), black(1), green(2), yellow(3), red(4) } TypeFactoryReset ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { press(0) } TypeFan1Status ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { ok(0), fail(1) } TypeAlarmTemp ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { none(0), minor(1), major(2) } -- Parameter definitions typeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LYNX product type name" ::= { paramEntry 1 } displayName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name of device (potentially user-defined), as stored in device-controller" ::= { paramEntry 2 } position OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Full-qualified position information (e.g. as used in address-field of remoteIF protocol)" ::= { paramEntry 3 } uptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Connection time of the device to this UI (in seconds)" ::= { paramEntry 4 } type OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device type code" ::= { paramEntry 5 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device version information" ::= { paramEntry 6 } statusColor OBJECT-TYPE SYNTAX TypeStatusColor MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED (red/green/yellow)" ::= { paramEntry 7 } statusColorRGB OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED as #RRGGBB" ::= { paramEntry 8 } statusText OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current status text (OK or error-details)" ::= { paramEntry 9 } factoryReset OBJECT-TYPE SYNTAX TypeFactoryReset MAX-ACCESS read-write STATUS current DESCRIPTION "Reset device to factory default values (set value to PRESS for execution)" ::= { paramEntry 10 } lock OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "Lock Device" ::= { paramEntry 11 } locate OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "toggle the locating function (yellow flashing master LED) ON/OFF" ::= { paramEntry 12 } gPO1Status OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the GPO (General Purpose Output) contact 1 on the back of the rack (Minor Alarm)" ::= { paramEntry 19 } gPO2Status OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the GPO (General Purpose Output) contact 2 on the back of the rack (Major Alarm)" ::= { paramEntry 20 } gPIStatus OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the GPI (General Purpose Input) contact on the back of the Rack (on/off)" ::= { paramEntry 21 } pSUTypeAndVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Type name of power supply unit" ::= { paramEntry 22 } pSUStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status of power supply unit" ::= { paramEntry 23 } pSUVoltage OBJECT-TYPE SYNTAX FixedPointValue1 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage of power supply unit" ::= { paramEntry 24 } pSUTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of power supply unit" ::= { paramEntry 25 } externalVoltage OBJECT-TYPE SYNTAX FixedPointValue1 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage of external DC power supply" ::= { paramEntry 26 } slotStatus1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 1: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 27 } slotStatus2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 2: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 28 } slotStatus3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 3: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 29 } slotStatus4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Status 4: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 30 } slotStatusPSU1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status PSU 1: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 31 } slotStatusPSU2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Status PSU 2: if present: set to name-and-version as in VVV.VV.VV" ::= { paramEntry 32 } fan1Status OBJECT-TYPE SYNTAX TypeFan1Status MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of fan 1" ::= { paramEntry 33 } fan2Status OBJECT-TYPE SYNTAX TypeFan1Status MAX-ACCESS read-only STATUS current DESCRIPTION "Current status of fan 2" ::= { paramEntry 34 } alarmTemp OBJECT-TYPE SYNTAX TypeAlarmTemp MAX-ACCESS read-write STATUS current DESCRIPTION "Specify whether a High Temperature event shall trigger a Major or Minor Alarm (GPO contact) or none of the above." ::= { paramEntry 35 } alarmVolt OBJECT-TYPE SYNTAX TypeAlarmTemp MAX-ACCESS read-write STATUS current DESCRIPTION "Specify whether a Voltage out of range event shall trigger a Major or Minor Alarm (GPO contact) or none of the above." ::= { paramEntry 36 } alarmRPS1 OBJECT-TYPE SYNTAX TypeAlarmTemp MAX-ACCESS read-write STATUS current DESCRIPTION "Specify whether a One RPS missing event shall trigger a Major or Minor Alarm (GPO contact) or none of the above." ::= { paramEntry 37 } alarmFanFail OBJECT-TYPE SYNTAX TypeAlarmTemp MAX-ACCESS read-write STATUS current DESCRIPTION "Specify whether a Fan Failure event shall trigger a Major or Minor Alarm (GPO contact) or none of the above." ::= { paramEntry 38 } hotsync OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "HotSync adds data security as a reliable and automatic recovery mechanism for configuration data of individual processing devices.
HotSync is enabled as a function of a RackController and applies to all devices in the controllers stack, i.e. in the local RackFrame and in connected Extensions, if any.
When enabled, HotSync automatically maintains a dynamic copy of the current configuration for all devices. The backup copy is stored inside the controller. You can think of this mechanism as if a backup copy of the device-settings were stored in the slot.
If you ever have to replace a processing board, and you bring a new device of the same type into the same slot, then HotSync will automatically copy the last valid settings from the controllers backup-memory into the new board" ::= { paramEntry 39 } sNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Number" ::= { paramEntry 41 } -- Parameter table paramTable OBJECT-TYPE SYNTAX SEQUENCE OF ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of RFR5041 parameters" ::= { sw393 1 } paramEntry OBJECT-TYPE SYNTAX ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of RFR5041 parameters" INDEX { IMPLIED position } ::= { paramTable 1 } ParamEntry ::= SEQUENCE { typeName DisplayString, displayName DisplayString, position OCTET STRING, uptime TimeTicks, type DisplayString, version DisplayString, statusColor TypeStatusColor, statusColorRGB DisplayString, statusText DisplayString, factoryReset TypeFactoryReset, lock OnOffValue, locate OnOffValue, gPO1Status OnOffValue, gPO2Status OnOffValue, gPIStatus OnOffValue, pSUTypeAndVersion DisplayString, pSUStatus DisplayString, pSUVoltage FixedPointValue1, pSUTemperature Integer32, externalVoltage FixedPointValue1, slotStatus1 DisplayString, slotStatus2 DisplayString, slotStatus3 DisplayString, slotStatus4 DisplayString, slotStatusPSU1 DisplayString, slotStatusPSU2 DisplayString, fan1Status TypeFan1Status, fan2Status TypeFan1Status, alarmTemp TypeAlarmTemp, alarmVolt TypeAlarmTemp, alarmRPS1 TypeAlarmTemp, alarmFanFail TypeAlarmTemp, hotsync OnOffValue, sNumber DisplayString } -- Conformance statements conformance OBJECT-IDENTITY STATUS current DESCRIPTION "Conformance declaration of RFR5041" ::= { sw393 2 } paramGroup OBJECT-GROUP OBJECTS { typeName, displayName, position, uptime, type, version, statusColor, statusColorRGB, statusText, factoryReset, lock, locate, gPO1Status, gPO2Status, gPIStatus, pSUTypeAndVersion, pSUStatus, pSUVoltage, pSUTemperature, externalVoltage, slotStatus1, slotStatus2, slotStatus3, slotStatus4, slotStatusPSU1, slotStatusPSU2, fan1Status, fan2Status, alarmTemp, alarmVolt, alarmRPS1, alarmFanFail, hotsync, sNumber } STATUS current DESCRIPTION "Conformance group containing all device parameters" ::= { conformance 1 } paramCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance specification" MODULE -- This module MANDATORY-GROUPS { paramGroup } ::= { conformance 2 } END