-- Machine generated MIB file, do not edit! -- -- MIB file for SVD5012, type code 08.84, software label 147 -- Generated on Tuesday, 09-Aug-16 14:24:40 UTC -- CVS $Id: SVD5012_0884_sw147.mib,v 1.11 2016/08/09 14:24:42 jvo Exp $ -- -- Copyright 2003-2016 by LYNX Technik AG -- -- These coded instructions, statements, and computer programs contain -- unpublished proprietary information written by LYNX Technik AG and -- are protected by Federal copyright law. They may not be disclosed -- to third parties or copied or duplicated in any form, in whole or -- in part, without the prior written consent of LYNX Technik AG. -- SVD5012-0884-sw147-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, Integer32, TimeTicks FROM SNMPv2-SMI -- RFC2578 TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC -- RFC2579 MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF -- RFC2580 mib-modules, products, FixedPointValue1, FixedPointValue2, FixedPointValue3, OnOffValue FROM LYNX-SMI; svd5012-0884-sw147 MODULE-IDENTITY LAST-UPDATED "201608091424Z" ORGANIZATION "LYNX Technik AG" CONTACT-INFO "LYNX Technik AG Brunnenweg 3 64331 Weiterstadt http://www.lynx-technik.com mailto:support@lynx-technik.com" DESCRIPTION "MIB module definition for SVD5012, type code 08.84, software label 147" REVISION "201608091424Z" DESCRIPTION "Generated by LYNX Asset Database" ::= { mib-modules 2180147 } svd5012-0884 OBJECT-IDENTITY STATUS current DESCRIPTION "LYNX device type SVD5012" ::= { products 2180 } sw147 OBJECT-IDENTITY STATUS current DESCRIPTION "Software label 147" ::= { svd5012-0884 147 } -- Type definitions TypeStatusColor ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { unknown(0), black(1), green(2), yellow(3), red(4) } TypeFactoryReset ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { press(0) } TypeMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { automatic(0), automaticLatched(1), manual(2), gPIControlled(3) } TypeOut ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { main(0), bypass(1) } TypeMain ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { present(0), invalid(1), missing(2) } TypeEventSDIInput1NoInputSNMP ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enumeration" SYNTAX INTEGER { none(0), onOnly(1), offOnly(2), onOff(3) } -- Parameter definitions typeName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "LYNX product type name" ::= { paramEntry 1 } displayName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Name of device (potentially user-defined), as stored in device-controller" ::= { paramEntry 2 } position OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..63)) MAX-ACCESS read-only STATUS current DESCRIPTION "Full-qualified position information (e.g. as used in address-field of remoteIF protocol)" ::= { paramEntry 3 } uptime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Connection time of the device to this UI (in seconds)" ::= { paramEntry 4 } type OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device type code" ::= { paramEntry 5 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device version information" ::= { paramEntry 6 } statusColor OBJECT-TYPE SYNTAX TypeStatusColor MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED (red/green/yellow)" ::= { paramEntry 7 } statusColorRGB OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current color of the Devices Master LED as #RRGGBB" ::= { paramEntry 8 } statusText OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current status text (OK or error-details)" ::= { paramEntry 9 } factoryReset OBJECT-TYPE SYNTAX TypeFactoryReset MAX-ACCESS read-write STATUS current DESCRIPTION "Reset device to factory default values (set value to PRESS for execution)" ::= { paramEntry 10 } lock OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "Lock Device" ::= { paramEntry 11 } locate OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "toggle the locating function (yellow flashing master LED) ON/OFF" ::= { paramEntry 12 } eventSDIInput1NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Warning Event: SDI Input 1 No Input" ::= { paramEntry 14 } eventSDIInput2NoInput OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Warning Event: SDI Input 2 No Input" ::= { paramEntry 15 } mode OBJECT-TYPE SYNTAX TypeMode MAX-ACCESS read-write STATUS current DESCRIPTION "Configure general mode of operation: Automatic, Latched, Manual, GPI" ::= { paramEntry 16 } out OBJECT-TYPE SYNTAX TypeOut MAX-ACCESS read-write STATUS current DESCRIPTION "Select Source for the main output" ::= { paramEntry 17 } main OBJECT-TYPE SYNTAX TypeMain MAX-ACCESS read-only STATUS current DESCRIPTION "Main Input status" ::= { paramEntry 18 } bypass OBJECT-TYPE SYNTAX TypeMain MAX-ACCESS read-only STATUS current DESCRIPTION "Bypas Input status" ::= { paramEntry 19 } reclock OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "select SDI reclocking" ::= { paramEntry 20 } invert OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-write STATUS current DESCRIPTION "select SDI invert" ::= { paramEntry 21 } boardID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "BoardID" ::= { paramEntry 22 } eventSDIInput1NoInputSNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 1 No Input" ::= { paramEntry 23 } eventSDIInput2NoInputSNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: SDI Input 2 No Input" ::= { paramEntry 24 } sNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Number" ::= { paramEntry 25 } eventlostinput1 OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Error Event: lost input 1 (input signal 1 can not be detected)" ::= { paramEntry 26 } eventlostinput2 OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Error Event: lost input 2 (input signal 2 can not be detected)" ::= { paramEntry 27 } eventinvalidinput1 OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Error Event: invalid input 1 (PLL on input 1 could not lock on input signal)" ::= { paramEntry 28 } eventinvalidinput2 OBJECT-TYPE SYNTAX OnOffValue MAX-ACCESS read-only STATUS current DESCRIPTION "Error Event: invalid input 2 (PLL on input 2 could not lock on input signal)" ::= { paramEntry 29 } eventlostinput1SNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: lost input 1 (input signal 1 can not be detected)" ::= { paramEntry 30 } eventlostinput2SNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: lost input 2 (input signal 2 can not be detected)" ::= { paramEntry 31 } eventinvalidinput1SNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: invalid input 1 (PLL on input 1 could not lock on input signal)" ::= { paramEntry 32 } eventinvalidinput2SNMP OBJECT-TYPE SYNTAX TypeEventSDIInput1NoInputSNMP MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP Trap for Event: invalid input 2 (PLL on input 2 could not lock on input signal)" ::= { paramEntry 33 } -- Parameter table paramTable OBJECT-TYPE SYNTAX SEQUENCE OF ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of SVD5012 parameters" ::= { sw147 1 } paramEntry OBJECT-TYPE SYNTAX ParamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the table of SVD5012 parameters" INDEX { IMPLIED position } ::= { paramTable 1 } ParamEntry ::= SEQUENCE { typeName DisplayString, displayName DisplayString, position OCTET STRING, uptime TimeTicks, type DisplayString, version DisplayString, statusColor TypeStatusColor, statusColorRGB DisplayString, statusText DisplayString, factoryReset TypeFactoryReset, lock OnOffValue, locate OnOffValue, eventSDIInput1NoInput OnOffValue, eventSDIInput2NoInput OnOffValue, mode TypeMode, out TypeOut, main TypeMain, bypass TypeMain, reclock OnOffValue, invert OnOffValue, boardID Integer32, eventSDIInput1NoInputSNMP TypeEventSDIInput1NoInputSNMP, eventSDIInput2NoInputSNMP TypeEventSDIInput1NoInputSNMP, sNumber DisplayString, eventlostinput1 OnOffValue, eventlostinput2 OnOffValue, eventinvalidinput1 OnOffValue, eventinvalidinput2 OnOffValue, eventlostinput1SNMP TypeEventSDIInput1NoInputSNMP, eventlostinput2SNMP TypeEventSDIInput1NoInputSNMP, eventinvalidinput1SNMP TypeEventSDIInput1NoInputSNMP, eventinvalidinput2SNMP TypeEventSDIInput1NoInputSNMP } -- Conformance statements conformance OBJECT-IDENTITY STATUS current DESCRIPTION "Conformance declaration of SVD5012" ::= { sw147 2 } paramGroup OBJECT-GROUP OBJECTS { typeName, displayName, position, uptime, type, version, statusColor, statusColorRGB, statusText, factoryReset, lock, locate, eventSDIInput1NoInput, eventSDIInput2NoInput, mode, out, main, bypass, reclock, invert, boardID, eventSDIInput1NoInputSNMP, eventSDIInput2NoInputSNMP, sNumber, eventlostinput1, eventlostinput2, eventinvalidinput1, eventinvalidinput2, eventlostinput1SNMP, eventlostinput2SNMP, eventinvalidinput1SNMP, eventinvalidinput2SNMP } STATUS current DESCRIPTION "Conformance group containing all device parameters" ::= { conformance 1 } paramCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Compliance specification" MODULE -- This module MANDATORY-GROUPS { paramGroup } ::= { conformance 2 } END